PSI - Issue 60
Aritro Chatterjee et al. / Procedia Structural Integrity 60 (2024) 13–19 Aritro Chatterjee, Arpan Mandal, Anoj Giri / Structural Integrity Procedia 00 (2019) 000–000
17
5
fixed in U axis direction and V displacement refers to how much displacement faced by the strain rosette, fixed in V axis direction. U-displacement scale varies from -7.1× 10 -3 mm to -6.2 × 10 -3 mm and V-displacement scale varies from -7× 10 -3 mm to -5.5 × 10 -3 mm. The strains in X & Y directions are shown in Fig. 5. Fig. 5a shows the strain along longitudinal direction and Fig. 5b represents the strain along transverse direction. For calculating Ꜫ x strain only virtual strain rosette along X axis is considered and for Ꜫ y virtual strain rosette along Y axis is considered. The scale of Ꜫ x and Ꜫ y varies 3 × 10 -4 to 12 × 10 -3 and -1.8 × 10 -3 to -0.4× 10 -3 respectively. After analyzing the strain data, the Ꜫ x and Ꜫ y are obtained as 548 and -611 macrostrains respectively.
V Disp.
U Disp.
Drilled Hole
Drilled Hole
` Fig.4. (a) Displacement field along U; (b) Displacement along V
Drilled Hole
Drilled Hole
Fig. 5. Relaxed strains: (a) Ꜫx strain; (b) Ꜫy strain
Made with FlippingBook Learn more on our blog