Issue 78
N. Naboulsi et alii, Fracture and Structural Integrity, 78 (2026) 74-95; DOI: 10.3221/IGF-ESIS.78.05
Fig. 4 shows tensile specimens printed at 90°, 45°, and 0°, with dimensions conforming to ISO 527-2 Type 5A. Fig. 5 presents tensile specimens printed at 90°, 45°, and 0° with different infill densities, before and after tensile testing, as well as an example of a specimen subjected to uniaxial tensile loading.
Material
Infill density
Printing Orientation
Number of specimens
0°
5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5
20%
45° 90° 45° 90° 0° 45° 90° 45° 90° 45° 90° 45° 90° 0° 0° 0° 0°
40%
PLA-CB
60%
80%
100%
Pure PLA (As a reference)
100%
5 Table 2: Experimental matrix of tensile tests performed on PLA-CB and pure PLA specimens.
Figure 4: Tensile specimens printed at 90°, 45°, and 0°, with dimensions according to ISO 527-2 type 5A.
79
Made with FlippingBook Online newsletter creator