D. D. Joshi et alii, Fracture and Structural Integrity, 78 (2026) 315-345; DOI: 10.3221/IGF-ESIS.78-19
Qiu et al. [30] Experimental and analytical Ramin et al. [33] Experimental and numerical
Beam-column assembly (Two bays frame)
One-quarter scale
Steel cable
External steel cables installed beneath each beam span with different diameter of cable
Quasi-static loading (0.5 to 5 mm/minute)
Middle column
Beam-column two storey assembly (Two bays frame)
One-half scale Middle column
Corrugated plate
Corrugated plates integrated into RC joints
Quasi-static loading
Table 2: Important parameters related to strengthening studies on reinforced concrete systems.
Author/ Main performance indicator Bao et al. [11] Load-displacement response, failure modes DIC analysis, ductility, energy dissipation
Failure modes
Main Findings
Limitation
• concrete crushing and spalling at junctions for control specimen • rupture of longitudinal rebars and stirrups • fracture and debonding of BFRP sheets along with rebar rupture for strengthened specimen • specimens exhibited flexural action, compressive arch action and catenary action stage • rebar rupture and concrete crushing in control specimen • rebar rupture and CFRP strip rupture in middle column and end column • slight debonding of the continuous CFRP strip near removed column • debonding of L shape strip • failure at beam ends in unstrengthened frame • failure at beam ends as well as regions around CFRP edges in retrofitted frame • severe diagonal crack formed at the center of the slab for control specimen • The failure of the strengthened specimens was mainly due to debonding of the CFRP laminates and severe cracks concentrated in the cut-off point of the CFRP sheets and strips • all three actions are observed for control specimen • concrete crushing and rebar rupture in control specimen
• BFRP strengthening enhanced the ultimate capacity by 39.31% at catenary action stage. • horizontal pull and ductility coefficient increased by 64.22% and 29.20% respectively. • BFRP strengthening delays the failure and effectively improved performance of corroded specimen • proposed strengthening schemes enhanced the load carrying in CAA and CA phases, with maximum increases of 23.80% and 66.70%, respectively. • the enhanced load resistance at the CA stage was mainly due to the continuous CFRP strips attached to the soffits • proposed CFRP retrofitting restored the frame structure to its original capacity. • “strong-column and weak-beam” mechanism considered during design enhanced the progressive collapse resistance higher effectiveness. 82.0% increase in the dynamic ultimate strength compared to control specimen • diagonally laminates oriented exhibiting CFRP
• discontinuity of beams beyond the end columns • absence of transverse beams and slab effect • limited improvement in capacity at compressive arch action
Liang et al. [12] Load-displacement response, response, displacement profiles, failure modes strain
• debonding of CFRP strip • strengthened CA capacity unable to enhance dynamic collapse resistance due to softening of load resistance
Li et al. [13] Load-displacement response,
• the presence of slab is not considered, which affects the retrofitting process in actual structure
crack
development failure modes
and
Qian and Li [14] Load-displacement response, force-displacement, energy response,
• debonding laminates
of
CFRP
restrict
the
laminate capacity • no use of anchors for CFRP laminates
strain
reaction
absorption,
failure modes
Chen et al. [16] Load-displacement response, horizontal displacement, strain
• strengthening scheme improved the load-bearing capacity by 18.5% and ductility by 3.09 times
• strengthening scheme failed to enter the CA stage