PSI - Issue 66

10

S. Skrobacz et al. / Procedia Structural Integrity 66 (2024) 11–25 S. Skrobacz¹², P. Krysi ń ski¹, S. Ma ł ys¹², T. Ł agoda² / Structural Integrity Procedia 00 (2025) 000–000

20

Table 6. Description of 2HY Joint for Sample PR-909 - Sketch of the Sample, Notes, and Detected Defects

Welding Position/Method

Type of Joint

Type of Weld

Filler Material

Shielding Gas

FW

a3

PB

131(robot)

AlMg4.5MnZr

I1 (Ar100%)

Sketch of the Sample

1: 2011: d ₘ ₐₓ = 0,2mm; d ₐ ≤ 0.6mm 2012 ≤ 2%

Notes, and Detected Defects

Figure 8. Macrographic Cross-Sections of Sample Number PR-909

4. Optimization of the Welding Process During the execution of working trials, adjustments were made to the optimization process, including refinements to the welding phases and the implementation of several modifications to the welding parameters. Below, I present the macrographic cross-sections along with the steps that were implemented.

Made with FlippingBook Ebook Creator