PSI - Issue 64

A. Cagnoni et al. / Procedia Structural Integrity 64 (2024) 951–958

958

8 Alessandro Cagnoni, Pierluigi Colombi, Marco A. Pisani, Tommaso D’Antino / Structural Integrity Procedia 00 (2019) 000–000

Harajli, M., Khairallah, N., and Nassif, H., 1999. Externally Prestressed Members: Evaluation of Second-Order Effects, Journal of Structural Engineering, 125(10), 1151–61. Harajli, M. H., 1993. Strengthening of concrete beams by external prestressing, PRECAST/PRESTRESSED CONCRETE INSTITUTE. JOURNAL, 38(6). Heydarinouri, H., Motavalli, M., Nussbaumer, A., and Ghafoori, E., 2021. Development of a Mechanical Wedge–Barrel Anchor for CFRP Rods: Static and Fatigue Behaviors, Journal of Composites for Construction, 25(3), 04021015. Jia, L., Wang, B., and Tafsirojjaman, T., 2022. Experimental Research on Bonded Anchorage of Carbon Fiber Reinforced Polymer Prestressed Strands, Polymers, 14(19), 4015. Khalafalla, O., Pour-Ghaz, M., ElSafty, A., and Rizkalla, S., 2019. Durability of CFRP strands used for prestressing of concrete structural members, Construction and Building Materials, 228, 116756. Mei, K., Sun, Y., Sun, S., Ren, X., and Zhao, J., 2020. Experimental investigation on the mechanical properties of a novel anchorage for carbon fiber reinforced polymer (CFRP) tendon, Composite Structures, 234, 111704. Micelli, F., and Nanni, A., 2004. Durability of FRP rods for concrete structures, Construction and Building Materials, 18(7), 491–503. Najafabadi, E. P., Bazli, M., Ashrafi, H., and Oskouei, A. V., 2018. Effect of applied stress and bar characteristics on the short-term creep behavior of FRP bars, Construction and Building Materials, 171, 960–8. Pisani, M. A., 1999. Strengthening by Means of External Prestressing, Journal of Bridge Engineering, 4(2), 131–5. Saadatmanesh, H., and Tannous, F., 1999. Relaxation, Creep, and Fatigue Behavior of Carbon Fiber Reinforced Plastic Tendons, ACI Materials Journal, 96(2). Saeed, Y. M., Al-Obaidi, S. M., Al-hasany, E. G., and Rad, F. N., 2020. Evaluation of a new bond-type anchorage system with expansive grout for a single FRP rod, Construction and Building Materials, 261, 120004. Schmidt, J. W., Bennitz, A., Goltermann, P., and Ravn, D. L., 2012. External post-tensioning of CFRP tendons using integrated sleeve-wedge anchorage. Scott, P., and Lees, J. M., 2012. Effects of solution exposure on the combined axial-shear behaviour of unidirectional CFRP rods, Composites Part A: Applied Science and Manufacturing, 43(9), 1599–611. Shi, J., Wang, X., Wu, Z., and Zhu, Z., 2022. Optimization of anchorage and deviator for concrete beams prestressed with external fiber reinforced polymer tendons, Composite Structures, 297, 115970. Song, S., Zang, H., Duan, N., and Jiang, J., 2019. Experimental Research and Analysis on Fatigue Life of Carbon Fiber Reinforced Polymer (CFRP) Tendons, Materials (Basel, Switzerland), 12(20), 3383. Tan, K. H., and Tjandra, R. A., 2007. Strengthening of RC Continuous Beams by External Prestressing, Journal of Structural Engineering, 133(2), 195–204. Terrasi, G. P., Affolter, C., and Barbezat, M., 2011. Numerical Optimization of a Compact and Reusable Pretensioning Anchorage System for CFRP Tendons, Journal of Composites for Construction, 15(2), 126–35. Wang, Y. C., Wong, P. M. H., and Kodur, V., 2007. An experimental study of the mechanical properties of fibre reinforced polymer (FRP) and steel reinforcing bars at elevated temperatures, Composite Structures, 80(1), 131–40. Wu, Z., Wang, X., Iwashita, K., Sasaki, T., and Hamaguchi, Y., 2010. Tensile fatigue behaviour of FRP and hybrid FRP sheets, Composites Part B: Engineering, 41(5), 396–402. Yang, D., Zhang, J., Song, S., Zhou, F., and Wang, C., 2018. Experimental Investigation on the Creep Property of Carbon Fiber Reinforced Polymer Tendons under High Stress Levels, Materials, 11(11), 2273. Ye, Y., and Guo, Z., 2011. Experimental Investigation on the Anchorage Performance of Clamping Anchors for Carbon Fiber Reinforced Polymer Rods, Advanced Science Letters, 4, 922–6. Zhang, B., and Benmokrane, B., 2004. Design and evaluation of a new bond-type anchorage system for fiber reinforced polymer tendons, Canadian Journal of Civil Engineering, 31(1), 14–26. Zhou, F., Zhang, J., Song, S., Yang, D., and Wang, C., 2019. Effect of Temperature on Material Properties of Carbon Fiber Reinforced Polymer (CFRP) Tendons: Experiments and Model Assessment, Materials, 12(7), 1025. Zou, P. X. W., 2003. Long-Term Properties and Transfer Length of Fiber-Reinforced Polymers, Journal of Composites for Construction, 7(1), 10–9. Züst, G.-L., Ott, V., and Terrasi, G. P., 2022. Development of a Pretensioning Anchorage for Sand-Coated CFRP Tendons: Modeling and Validation, Polymers, 14(24), 5531.

Made with FlippingBook Digital Proposal Maker