PSI - Issue 64
Massimiliano Ferraioli et al. / Procedia Structural Integrity 64 (2024) 1017–1024 Ferraioli et al./ Structural Integrity Procedia 00 (2019) 000–000
1022
6
Table 4. Parameters of the bilinear equivalent SDOF system of endoskeleton ( E )
d p [mm]
d p
V p
V y
d y
K e
*
(E)
(E)
(E)
(E)
(E)
h
Direction
r (E)
(E)
[mm]
[kN]
[kN]
[mm]
[kN/mm]
[%]
X Y
100 73.53 912 490 9.15 75 56.82 1413 760 6.86
9.12
0.087 10.93 11.1
18.84 0.086 10.93 11.6
Table 5. Distribution of strength and stiffness of dissipative braces over the height X-Direction Y-Direction
Mass [kN ꞏ s 2 /mm]
F i [kN]
F i [kN]
V y,i [kN]
K i,tot [kN/mm]
K i(HBFX1,2) [kN/mm]
K i(HBFX3,4) [kN/mm]
V y,i [kN]
K i,tot [kN/mm]
K i(HBFY) [kN/mm]
Floor
2 3 4
0.33231 0.33039 0.26539
0.3067 86
490 304.2
69.8 50.9 29.3
82.3 60.0 34.9
0.3684 146 760 360.3 0.7616 299 615 273.0 1.0000 316 316 240.3
90.1 68.3 60.1
0.6542 182 405 221.6 1.0000 223 223 128.3
Table 6. Type, design strength ( N D ), and stiffness ( K D ) of the HBF dampers, stiffness ( K B ), and type of the braces. HBF1X HBF2X HBF3X= HBF4X HBF5Y, HBF6Y, HBF7Y, HBF8Y Floor N D [kN] K D [kN/mm] K B [kN/mm] Type N D [kN] K D [kN/mm] K B [kN/mm] Type N D [kN] K D [kN/mm] K B [kN/mm] Type N D [kN] K D [kN/mm] K B [kN/mm] Type 2 130 168 234 168,3/12 141 203 264 168,3/12 180 256 357 193,7/16 130 168 234 168,3/12 3 107 154 159 168,3/8 117 168 264 168,3/12 148 203 234 168,3/12 107 154 159 168,3/8 4 60 154 156 168,3/8 66 154 175 168,3/8 83 154 156 168,3/8 60 154 156 168,3/8
a) b) Fig. 6. a) Bilinear idealization of the retrofitted Structure (Step 1) ( S ); b) Bilinear idealization of the Endoskeleton ( E ).
a)
b) Fig. 7. a) Layout of the dissipative braces; b) Front view of the Damped Brace ( DB )
Made with FlippingBook Digital Proposal Maker