Fig. 1. Lightning rod: (a) Pole geometry; (b) Intersecting joint sections; (c) Connection between the pole and the base plate.

(a)

(b)

Fig. 2. Pull and release tests: (a) Picture ofthe tests conducted for the dynamic characterization of the lightning rod; (b) Top displacement corresponding to the first mode of vibration.

Table 1. Natural frequencies (n j ) and structural damping (  s,i ) of the lightning rod.

Mode i n i [Hz] (FEM)

n i [Hz] (Experimental)

 s,i [%] (Experimental)

 s,i [%] (CNR, 2019)

1 2

1.00 4.13

0.90 3.60

0.30 0.10

0.20 0.20