Patrícia C. Raposo et al. / Procedia Structural Integrity 5 (2017) 1102–1107 Patrícia C. Raposo et al. / Structural Integrity Procedia 00 (2017) 000 – 000

1106

5

at points P11, P12, P13, P14, P20 and P21.

Table 4. Results for the north facade (adapted from: [8]).

Measuring points

°C

°C at 50cm

% RH

P1 P2 P3 P4 P5 P6 P7 P8 P9

21.5 21.6 21.6 21.7 21.6 21.8 21.9 21.7 21.9 21.6 22.0 22.1 22.0 21.9 22.0 22.1 22.0 22.1 22.0 22.1 22.0 22.1 22.1 22.0 22.0 22.0

21.4 21.5 21.5 21.6 21.5 21.5 21.6 21.6 21.5 21.5 22.0 22.0 21.9 21.9 21.9 22.0 22.0 22.0 21.9 22.0 22.1 22.1 22.1 22.0 22.1 22.1

25 25 22 15 22 24 25 28 28 8

P10 P11 P12 P13 P14 P15 P16 P17 P18 P19 P20 P21 P22 P23 P24 P25 P26

5 5 5 5

14 15

6

14

6 5 5 7

19

6

10 15

Fig. 5. Location of the network points of the north facade (image from: [8]).

3. Conclusions In the current work was developed an observation network of measuring points of temperature and humidity of the facade walls, associated with visual inspection, in order to draw conclusions about the origin of the water presence in the structural walls, and develop a rehabilitation plan according to it. The Northeast and Northwest walls are the