PSI - Issue 44
Caprino Amedeo et al. / Procedia Structural Integrity 44 (2023) 1578–1585 A. Caprino et al./ Structural Integrity Procedia 00 (2022) 000 – 000
1581
4
Table 2. Environmental monitoring system
Sensor
Location
Monitoring period
Acquisition interval
Parameter
Measurement
Temperature
°C
21/10/2013 – still active 21/10/2013 – still active
TRH1
Interior
1 hour
Humidity
%
Temperature
°C
TRH2
Exterior
1 hour
Humidity
%
Last, the same satellite displacement data are correlated with environmental measurements supplied by “Padova 234” local meteorological statio n (available at https://www.arpa.veneto.it/arpavinforma), held by ARPA Veneto and described in Table 3.
Table 3. Meteorological station
Name
Location
Monitoring period
Acquisition interval
Parameter
Measurement
Mean temperature Mean humidity
°C
Lat. 45,40496348 Lon. 11,90848323
01/01/2012 31/12/2021
Daily
Padova 234
%
3. Results The PSInSAR analysis allows to detect a high number of MP inside the AOI. The interferometric process identifies 514415 points in the ascending orbit and 678521 points in the descending one.
a)
b)
c)
d)
Fig. 2. Displacement velocity interpolated maps: mean LOS displacement velocity of the ascending (a) and descending (b) dataset; real displacement velocity in the vertical (c) and horizontal (d) direction
Made with FlippingBook flipbook maker