PSI - Issue 37

Sonia Djenad et al. / Procedia Structural Integrity 37 (2022) 321–329 Djenad et al / Structural Integrity Procedia 00 (2019) 000 – 000

323 3

5CS4B1

5CS4B2

5CS4B3

5CS4

Fig. 1. A Summary of simulated confined cylinders.

Table 1. Geometrical characteristics of FRP Strips used for partially confinement.

Number of FRP Strips

FRP Strips width (cm)

FRP Strips thickness (cm)

FRP

Strips

Specimens

spacing (cm)

3CS1 3CS2 3CS3 5CS1 5CS2 5CS3 5CS4

130

3

20

1

45 25 55 45 35 25

5

20

1

5CS4E1 5CS4E2 5CS4E3 5CS4E4

2 3 4 5

5

20

25

5CS4E4B1 5CS4E4B2 5CS4E4B3

20 30 40

5

5

25

Made with FlippingBook Ebook Creator