PSI - Issue 22
Manuel Angel Díaz García et al. / Procedia Structural Integrity 22 (2019) 313–321 Manuel Ángel Díaz García/ Structural Integrity Procedia 00 (2019) 000 – 000
316
4
possible to consider larger critical crack sizes (F t3 ). Once again, it is necessary to check whether the critical crack obtained is detectable by visual inspection methods or not.
Start
NO
Is there crack? Fr
End
YES
Inspection threshold size
Structural and integrity assessment. Ft1
YES
YES
Is Ft1 detectable?
Control Plan or repair
Ft1>Fr
NO
NO
End
Refinement calculation IA. Ft2
YES
YES
Is Ft2 detectable?
Control Plan or repair
Ft2>Fr
NO
Reduce inspection threshold
NO
End
NO
Structural redundancy? Ft3
YES
YES
YES
Is Ft3 detectable?
Ft3>Fr
NO
NO
Control Plan or repair
Repair
End
End
Figure 2. Flowchart of the alternative structural integrity assessment methodology for steel bridges.
Made with FlippingBook Digital Publishing Software