PSI - Issue 2_A

Author name / Structural Integrity Procedia 00 (2016) 000 – 000

9

Ulf Stigh et al. / Procedia Structural Integrity 2 (2016) 235–244

243

(b)

(a)

3

2

1 P (kN)

(c)

0 20 40 60 80 0

 (mm)

Fig. 9. Load case A: Mechanical load. (a) Load vs. displacement in the loading direction; (b) Deformed geometry with von Mises’ effective stresses [MPa], with scale factor one; (c) Life fraction D in the isolated deformed tape viewed from above.

(b)

(a)

(c)

Fig. 10. Load case B: Thermal load. (a) Deformed geometry with scale factor one and size of displacement; (b) Deformed geometry with scale factor 300 and von Mises’ stress [MPa]; (c) Isolated tape in deformed geometry with total deformation of tape 2 2 2 1 2 w v v  