PSI - Issue 18
Fokion Oikonomidis et al. / Procedia Structural Integrity 18 (2019) 142–162 Dr Fokion Oikonomidis/ Structural Integrity Procedia 00 (2019) 000 – 000
158
17
Machined notch
Fatigue pre-crack and extension during the test
Brittle fracture created in breaking sample open at end of test
Fig. 22. Post-test fracture appearance of the tested chain link (general view). Magnification indicated by the millimetre scale marker.
Fig. 23. Post-test fracture appearance of the EDM notch and the fatigue pre-crack and crack growth from testing. Magnification indicated by the millimetre scale marker.