PSI - Issue 14
Sanjeev M Kavale et al. / Procedia Structural Integrity 14 (2019) 584–596 Sanjeev M. Kavale, Krishnaraja G Kodancha, Nagaraj Ekbote / Structural Integrity Procedia 00 (2018) 000–000
588
5
stress with variation of Poisson’s ratio for 2D specimen for both plane stress and plane strain conditions. This clearly demands the need for 3D analyses.
1000 (B)
1050 (A)
-15 -12 -9 -6 -3 0 3 6 9 12 15 600 650 700 750 800 850 900 950 SENB a/W=0.50 B=25.4mm = 0.20 = 0.25 = 0.30 = 0.35 = 0.40 = 0.45
1000
950
1/2
1/2
900
= 0.20 = 0.25 = 0.30 = 0.35 = 0.40 = 0.45
SENB a/W=0.50 B=3mm
850
800 K I in MPa(mm)
K I in MPa(mm)
750
-1.5 -1.0 -0.5 0.0 0.5 1.0 1.5
B in mm
B in mm
Fig. 3 Variation of K I in SENB specimen along the crack-front for various Poisson’s ratio and specimen thickness (A) 3mm and (B) 25.4mm
(B)
1100 (A)
1100
1050
1000
1000
1/2
900
1/2
950
= 0.20 = 0.25 = 0.30 = 0.35 = 0.40 = 0.45
= 0.20 = 0.25 = 0.30 = 0.35 = 0.40 = 0.45
800
900
CT a/W=0.50 B=25.4mm
CT a/W=0.50 B=3mm
850 K I in MPa(mm)
700 K I in MPa(mm)
800
600
750
-1.5 -1.0 -0.5 0.0 0.5 1.0 1.5
-15 -10
-5
0
5
10
15
B in mm
B in mm
Fig. 4 Variation of K I in CT specimen along the crack-front for various Poisson’s ratio and specimen thickness (A) 3mm and (B) 25.4mm
-8 -6 -4 -2 0 2 4 6 8 650 700 750 800 850 900 950 1000 1050 (B) SENB a/W=0.50 B=12.7mm K I in MPa(mm) 1/2 B in mm = 0 = 0.20 = 0.25 = 0.30 = 0.35 = 0.40 = 0.45
1000 1050 1100 (A)
-8 -6 -4 -2 0 2 4 6 8 650 700 750 800 850 900 950 CT a/W=0.50 B=12.7mm = 0 = 0.20 = 0.25 = 0.30 = 0.35 = 0.40 = 0.45
1/2
K I in MPa(mm)
B in mm
Fig. 5 Variation of K I along the crack-front for various Poisson’s ratio for a/W =0.50 and B/W =0.50 for (A) CT specimen and (B) SENB specimen