PSI - Issue 14

N. Venkateswaran et al. / Procedia Structural Integrity 14 (2019) 627–633 N.Venkateswaran/ Structural Integrity Procedia 00 (2018) 000–000

632

6

Fig. 4. (a) von-Mises stress on Assy. mounting Bracket when 50 g Shock in X-direction

Fig. 4. (b) von-Mises stress on Assy. mounting Bracket when 50 g Shock in Y-direction

Fig. 4. (c) von-Mises stress on Assy. mounting Bracket when 50 g Shock in Z-direction

5.4 Response Spectrum analysis Response spectrum analysis was also carried out on the assembly of mounting bracket with the given specification. Figure 5 shows the amplitude curve of Power Spectrum Density (PSD) vs Frequency. It is to be noted that the stress distribution is very low in this case also.