PSI - Issue 10
I. Iliopoulos et al. / Procedia Structural Integrity 10 (2018) 295–302
300
I. Iliopoulos et al. / Structural Integrity Procedia 00 (2018) 000 – 000
6
5 o C
7 o C
10 o C
Initial
Blank
Epoxy
PU
Acrylic
Fig. 4. Condensation effect at 40 o C (%RH=100), (Red PLA 3D printed protective cover for the thermocouple is visible).
Table 1. Coatings’ features and water collection rates (ml· m -1 · h -1 )
Sample
Primer Thickness
Topcoat thickness
Topcoat Mass
Experimental conditions
20 o C – 100% RH
40 o C – 100% RH
5 o C * 0.262 0.354 0.348 0.313
7 o C * 0.250 0.297 0.357 0.308
10 o C *
5 o C * 1.010 1.790 1.992 1.885
7 o C * 1.093 1.845 1.980 1.838
10 o C *
( μ m)
( μ m)
(mg)
Blank
n/a
n/a
n/a
0.281 0.223 0.380 0.313
1.059 1.845 1.987 1.922
PU
50 55
110 120 150
55 55 60
Epoxy Acrylic
n/a
* Sample temperature
Fig. 5. (a) Potentiodynamic polarization curves of samples and (b) Open current potential (OCP) measurements in 3.5% wt NaCl.