PSI - Issue 70
Jaiyash Jaiswal et al. / Procedia Structural Integrity 70 (2025) 596–603
600
0.05
0
0
6
86
26
46
66
-0.05
110
130
150
170
190
210
230
250
270
290
310
334
354
374
394
414
420
-0.1
-0.15
-0.2
Deflection (m)
-0.25
-0.3
Span (m)
E=1.65E08
E=1.96E08
E=2.1E08
Fig.2. Variation in deflection of longitudinal girder with span for different cable elasticity
26000 27000 28000 29000 30000 31000 32000 33000 34000 35000
3200 3300 3400 3500 3600 3700 3800 3900 4000
m)
Tower Base moment (kN-m)
E=1.65E08 E=1.96E08 E=2.1E08
E=1.65E08 E=1.96E08 E=2.1E08
Modulus of elasticity
Max. girder bending moment (kN
Modulus of elasticity
Fig.4. Variation in Max. girder bending moment for different cable elasticity
Fig.3. Variation in Tower base moment for different cable elasticity
270 280 290 300 310 320 330 340 350 360 370
0.115 0.12 0.125 0.13 0.135 0.14 0.145 0.15 0.155
Tower top deflection (m)
Shear force Tower base (kN)
E=1.65E08
E=1.96E08
E=2.1E08
E=1.65E08 E=1.96E08 E=2.1E08
Modulus of elasticity
Modulus of elasticity
Fig.5. Variation in Tower top deflection for different cable elasticity
Fig.6. Variation in Tower base shear force for different cable elasticity
Made with FlippingBook - Online catalogs