Saim Raza et al. / Procedia Structural Integrity 64 (2024) 1200–1207 Raza / Structural Integrity Procedia 00 (2024) 000 – 000
1206
7
expected to have the highest cracking load, owing to the absence of stress concentration. Conversely, nearly half the cracking load can be expected for all corrugated architectures, with negligible differences among them. This observation leads us to conclude that despite its singularity, the sharp edge remains the best choice for addressing corrugation in 3DP structures, provided that the singular region and its consequences are effectively managed.
(I)
(II)
(III)
(IV)
(a)
(b)
Fig. 7. Stress distribution ahead of the outermost bottom edge of the prism for four different architectures (a) at a specific load 210N, (b) at the cracking load.