PSI - Issue 60

Rohan Nair et al. / Procedia Structural Integrity 60 (2024) 93–114 Rohan Nair / Structural Integrity Procedia 00 (2023) 000–000

111

19

Fig. 24: Peak strain values recorded on LSI-RW1 (non adaptor side) strain gauges

4.4.

Ultimate pressure test (qualification tests):

The test article withstood the ultimate pressure test without any global yielding and the peak strain values achieved were under the marginal limits. Test article bursted at 18.57 bar (g) with the initiation of crack from inner side of long seam welds on the sub assembly consisting of adaptors. All strain values were confirming to specifications.

4.5.

DIC Results:

Two frames captured by the camera just before burst and post burst along with burst locations are shown in Fig. 25 and Fig. 26.

Fig. 25: Frame captured at 18.5 bar (just before burst)

Made with FlippingBook Learn more on our blog