PSI - Issue 60
7
Vaibhav Gangwar et al. / Procedia Structural Integrity 60 (2024) 123–135 Vaibhav Gangwar / StructuralIntegrityProcedia00(2024)000 – 000
130
Fig. 13. True stress vs. true plastic strain experimental data comparison of servo-hydraulic with DIC and Impact testing machine with strain gauge
Table1. MJC model constants for armor steel determined from servo-hydraulic test machine A (MPa) B G 1 G 2 r G 3 G 4 m 855.34 1789.69 0.98 0.014 0.84 - - -
Table2. MJC model constants for armor steel determined from CEAST 9350 test machine A (MPa) B G 1 G 2 r G 3 G 4 m 855.34 1789.69 0.917 0.078 0.29 - - -
4. Numerical model (MJC strength model) (parameter extraction also included) and J-C Failure model
Fig. 14. Quarter tensile specimen model