PSI - Issue 52
Minori Isozaki et al. / Procedia Structural Integrity 52 (2024) 176–186 Author name / Structural Integrity Procedia 00 (2019) 000 – 000
182
7
Instron (10 kN) universal testing machine at 0.5 mm/min until failure was confirmed. Displacement-load was measured in this test; a photograph of the fixture is shown in Fig. 8 (b).
Fig. 7. Adhesion of CF/PEEK and Aluminum blocks.
Fig. 8. Flatwise Test (a) Schematic diagram (b) Picture.
Fig. 9. Displacement-Load Diagram (Flatwise Test, Experiment).