Minori Isozaki et al. / Procedia Structural Integrity 52 (2024) 176–186 Author name / Structural Integrity Procedia 00 (2019) 000 – 000
178
3
ELECTRONICS CO.,LTD., Fig. 1). As shown in Fig. 2, three pieces of general-purpose PEEK mesh (#25, (CLEVER CO.,LTD.), thickness 0.13 mm, 30 mm square) were inserted between the adherends to form an ED. Four sets of two CFRTP laminates and three PEEK sheets were prepared, and the welding time was changed to 3 and 5 seconds, then welded twice each, named Specimen No. 1~4. CFRTP was successfully bonded to all four specimens.
Fig. 1. Ultrasonic Welder JP80s.
Fig. 2. Ultrasonic Welding for CFRTP (Using ED).
Compression shear tests were conducted on Specimen No. 1~4 bonded by ultrasonic welding. In this test, one side of the specimen was fixed by a jig and a load was applied to the other side, as shown in Fig. 3 (a). The jig used in this test is shown in Fig. 3(b). An Instron (10 kN) universal testing machine was used for this test. A 20 mm displacement was applied to the load cell at 1 mm/min and the displacement-load was measured.
Fig. 3. Compression Shear Test (a) Schematic diagram (b) Picture.