Hirotaka Tanabe et al. / Procedia Structural Integrity 5 (2017) 1005–1010 H Tanabe et al. / Structural Integrity Procedia 00 (2017) 000 – 000
1008
4
Fig. 3. Schematic illustration of hardness measurement area of cross-sectional surface
a
840W 900W 800W
1000 1200
0 200 400 600 800 Vickers hardness, HV
-3 -2 -1 0
1
2
3
Distance from center, mm
b
1000 1200
840W 900W 800W
0 200 400 600 800 Vickers hardness, HV
0
0.1 0.2 0.3 0.4 0.5
Distance from surface, mm
Fig. 4. Hardness distribution on the cross-sectional surface of the laser quenched specimen.
(a) Width direction (Depth = 50 m); (b) Depth direction