Jaroslav Václavík et al. / Procedia Structural Integrity 5 (2017) 1349–1354 Jaroslav Václavík et al. / Structural Integrity Procedia 00 (2017) 000 – 000
1352
4
b
a
Fig. 3. Installation of telemetry system on turbine generator shaft (a) scheme; (b) real image.
b
a
Fig. 4. (a) free shaft with installed measuring system; (b) receiving and controlling unit installed in turbine room.
Shaft 350 Ω
350 Ω
SIGNAL AMPLIFIER SV FLEX
20 m
D/A
RECEIVING ANTENA
MEASURING UNIT
RECEIVING UNIT
INDUSTRIAL PC
350 Ω
350 Ω
LAN
LAN
Fig. 5. Scheme of used chain of the measuring system
3.2. Software solution
The evaluation of stored data is performed using software module, build in program Matlab. This process is started each day in the controlling computer in parallel with the raw data transferee and pre-processing. The main task of the software is the evaluation of basic statistics of the monitoring signal, which are the mean, maximum, minimum and effective values. These values are added to the diagnostic file.