PSI - Issue 44
Available online at www.sciencedirect.com Available online at www.sciencedirect.com ScienceDirect Structural Integrity Procedia 00 (2022) 000–000
www.elsevier.com/locate/procedia
ScienceDirect
Procedia Structural Integrity 44 (2023) 2206–2213
© 2023 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (https://creativecommons.org/licenses/by-nc-nd/4.0) Peer-review under responsibility of the scientific committee of the XIX ANIDIS Conference, Seismic Engineering in Italy. Non-linear finite element analyses were performed to simulate the behavior of the specimens. To this end, a plane-stress model based on the smeared crack approach was implemented in the commercial code Diana 10.5. The simulations allowed to predict the response of both the strengthened walls and the un-strengthened (reference) member not included in the experimental campaign. The paper reports the results of the experimental tests including some important considerations on the observed failure mechanisms, the resistance and the displacement capacity of the walls. Moreover, the main results of the numerical simulations are reported and compared with those obtained from the tests in order to get a full comprehension of the different mechanisms affecting the response of the specimens. © 2022 The Authors. Published by ELSEVIER B.V. This is an open access article under the CC BY-NC-ND license ( https://creativecommons.org/licenses/by-nc-nd/4.0 ) Peer-review under responsibility of the scientific committee of the XIX ANIDIS Conference, Seismic Engineering in Italy Keywords: Out-of-plane bending; experimental tests ; masonry ; steel fiber reinforced mortar ; coating ; numerical analysis XIX ANIDIS Conference, Seismic Engineering in Italy Experimental and numerical evaluation of the out-of-plane bending behavior of masonry walls retrofitted by Steel Fiber Reinforced Mortar coating Sara S. Lucchini a , Luca Facconi a *,Fausto Minelli a , Giovanni A. Plizzari a a Dipartimento di Ingegneria Civile, Architettura, Territorio, Ambiente e di Matematica, Via Branze 43, 25123 Brescia, Italy Abstract The Out-of-Plane (OP) bending behavior of Un-Reinforced Masonry (URM) walls retrofitted by Steel Fiber Reinforced Mortar (SFRM) coating was investigated by performing in-situ experimental tests on two one-way vertically spanning walls. The latter were part of a full-scale two-story hollow block masonry building provided with seismic floor diaphragms and a 30 mm thick SFRM coating applied only on the external surface of the structure. One of the two test walls was tested under monotonic loading whereas the remaining one was subjected to reverse cyclic loading.
* Corresponding author. Tel.: +39.030.3711.275; fax: +39.030.3711.312. E-mail address: luca.facconi@unibs.it
2452-3216 © 2022 The Authors. Published by ELSEVIER B.V. This is an open access article under the CC BY-NC-ND license (https://creativecommons.org/licenses/by-nc-nd/4.0) Peer-review under responsibility of the scientific committee of the XIX ANIDIS Conference, Seismic Engineering in Italy
2452-3216 © 2023 The Authors. Published by ELSEVIER B.V. This is an open access article under the CC BY-NC-ND license (https://creativecommons.org/licenses/by-nc-nd/4.0) Peer-review under responsibility of the scientific committee of the XIX ANIDIS Conference, Seismic Engineering in Italy. 10.1016/j.prostr.2023.01.282
Made with FlippingBook flipbook maker