PSI - Issue 41
Chaaben Arroussi et al. / Procedia Structural Integrity 41 (2022) 752–758 Author name / Structural Integrity Procedia 00 (2019) 000–000
756
5
(a) (c) Fig5. Reaction of the moment bending versus the angular displacement on the different position on the elbow, (a) 10°, (b) 20° and (c) 45°. (b)
Table3 .Position of defect on the elbow
Position of defect
ɑ
0°
10°
45°
ɑ= 90° (M*)
1.94E+008
1.92 E+008
1.88 E+008
ɑ= 90°+30° (M*)
2.77E+008
3.58 E+008
1.76 E+008
Observations
X
ɑ= 90° (M*)
1.94 E+008
1.92 E+008
1.88 E+008
ɑ= 90°+45° (M*)
2.36 E+008
2.34 E+008
1.68 E+008
Observations
X
ɑ= 90° (M*)
1.94E+008
1.92 E+008
1.88 E+008
ɑ= 90°+55° (M*)
1.73E+008
1.68 E+008
1.71 E+008
Observations
X
X
X
ɑ= 90° (M*)
1.94E+008
1.92 E+008
1.88 E+008
ɑ= 90°+60° (M*)
1.45E+008
1.48 E+008
1.38 E+008
Observations
X
X
X
ɑ= 90° (M*)
1.94E+008
1.92 E+008
1.88 E+008
ɑ= 90°+90° (M*)
3.08 E+008
3.56 E+008
3.68 E+008
Observations
: Recommended, X : Not recommended. 2.2. Change the elbow pipe radius
The effect of bend moment and ratio radius on an different position of the corrosion default is presented in Figures 5 (a, b and c).Five ratio radius of elbow R/D=1, 1.5, 2, 3 and 5 are chosen with the three different position (0° , 20°
Made with FlippingBook - Online magazine maker