PSI - Issue 41
Mikhail Bannikov et al. / Procedia Structural Integrity 41 (2022) 518–526 Author name / Structural Integrity Procedia 00 (2019) 000–000
520
3
Microphones were glued to the rear surface of the sample using adhesive tape using acoustic gel as an interface between the receiving surface of the microphone and the sample. AMSY-6 systems allow measurement and analysis of discrete AE signals that cross a pre-set fixed or floating threshold level.
Fig. 1 - Experimental complex for testing: b) general view of the experimental complex: 1 - resonant testing machine Testronic-50, 2 - thermal imaging camera NECTH9100, 3 - LED lamp, 4 - camera of the LaVision digital image correlation system, 5 - fan, 6 - sample, 7 - microphones of the acoustic emission system AMSY-6.
a)
b)
Fig. 2 - PCM sample: a) with applied speckle structure, b) with installed acoustic emission sensors.