PSI - Issue 4
Rainer Boehm et al. / Procedia Structural Integrity 4 (2017) 71–78 Boehm, R. / Structural Integrity Procedia 00 (2017) 000 – 000
73
3
originate like they are usually used in the ultrasonic testing. The next step of development in the project WOLAXIM results in a prototype probe system that is illustrated in fig. 5.
Axis with bore hole
Possible element positions
Fluid
Conical array centered in the bore hole Ø 65 mm
Electronic scan
Fig. 3. Sketch of the cone shaped phased array for electronic rotation scan with a focused sound beam
bore hole
Büro für Technische Diagnostik (BTD)
flaw
test area
calculated soundfields in the plane on incidence and perpendicular
Fig. 4. Calculated sound fields of the first cone shaped phased array, Boehm et al. (2006)
Fig. 5. Probe system from the previous project WOLAXIM, Völz et al. (2012)