PSI - Issue 37
Aleksandar Sedmak et al. / Procedia Structural Integrity 37 (2022) 263–268 Author name / Structural Integrity Procedia 00 (2019) 000 – 000
264
2
Fig. 1. Vertical Kaplan turbine in hydro power plant “Djerdap 1” Turbaine cover consists of 4 segments (marked as 2-1, 3-2, 3-4 i 4-1), Fig. 2, made by welding of steel St 3, sl. 2. Chemical composition according to Russian standard GOST 380-94, [18], is shown in Tab.1, and basic tensile properties, according to GOST 14637-89, [19], in Tab. 2.
a)3D model
b) segment 4-1, back view
c) Segment 4-1, 3D model
d) segment 4-1, front view
Fig. 2, Turbine cover
Table 1. Chemical composition of steel St. 3. Standard C Si
Mn
S (max)
P (max)
GOST 380-94
0.14-0.22 0.15-0.3
0.4-0.65
0.05
0.05
Table 2. Mechanical properties of steel St. 3. Standard
R p0,2 [N/mm
2 ] R
m [N/mm
2 ] A
5,65 [ ]
GOST 14637-89
min. 235
370 - 480
min. 25
Made with FlippingBook Ebook Creator