PSI - Issue 34
Raffaele Sepe et al. / Procedia Structural Integrity 34 (2021) 172–177 R. Sepe / Structural Integrity Procedia 00 (2021) 000–000
175
4
Fig. 2. (a) Specimen manufacturing with highlight of the laser weld bead; (b) fatigue test specimen mounted onto the fatigue testing machine.
3. Results and discussion Specimens were cut out of from the welded plates in two different shapes according to the respective standards for static and fatigue tests. The measured stress-strain curves were reported in Figure 3 as a comparison between a welded and an as-built specimen (presented in Caiazzo et al. (2021)). Through this comparison, it can be stated that the LBW process did not degrade the static properties of the material. All two specimens tested statically reported the failure within the base material.
Fig. 3. Stress-strain curves for the laser welded AM specimens.
Made with FlippingBook Ebook Creator