Yuichi Otsuka et al. / Procedia Structural Integrity 28 (2020) 1018–1023 Y.Otsuka et al. / Structural Integrity Procedia 00 (2020) 000–000

1023

6

4. Summary

Damage evaluation on the interfaces between acetabular cup with porous simulated bone as well as within the porous simulated bone by cyclic compression was experimentally observed using using Infrared thermography(IR) and Acoustic emission(AE). Temperature changes detected by IR could indicate normal displacement of the acetabular cup and AE signals relating to interfacial damages also suggested rotational displacement of the acetabule cups. The result clearly demonstrated that the mechanical factor in aseptic loosening, which may induce displacements by degradation of fixaion, can also be a considerable one in determining how and when the loosening occurs.

References

[1] A. J. Tonino, M. Th?rin, and C. Doyle. Hydroxyapatite-coated femoral stems. Journal of Bone and Joint Surgery - Series B , 81(1):148–154, 1999. [2] Abu-Amer Y., Darwech I., and Clohisy JC. Aseptic loosening of total joint replacements: mechanisms underlying osteolysis and potential therapies. Arthritis Res Ther. , Suppl 1(Suppl 1):S6, 2007. [3] G.E. Lewinnek, J.L. Lewis, R. Tarr, C.L. Compere, and J.R. Zimmerman. Dislocations after total hip-replacement arthroplasties. Journal of Bone and Joint Surgery - Series A , 60 A(2):217–220, 1978. [4] T. Kalteis, M. Handel, T. Herold, L. Perlick, C. Paetzel, and J. Grifka. Position of the acetabular cup-accuracy of radiographic calculation compared to ct-based measurement. European Journal of Radiology , 58(2):294–300, 2006. [5] Y.-Y. Chung, J. Kim, C.H. Lim, K.-S. Kim, and Y.S. Lee. Measurement of extent of bone ongrowth and hydroxyapatite absorption in retrieved acetabular cups. Journal of Orthopaedic Science , 13(3):198–201, 2008. [6] Y. Otsuka, D. Kojima, and Y. Mutoh. Prediction of cyclic delamination lives of plasma-sprayed hydroxyapatite coating on ti6al4v substrates with considering wear and dissolutions. Journal of the Mechanical Behavior of Biomedical Materials , 64:113–124, 2016. [7] S. Lazarinis, J. Krrholm, and N.P. Hailer. Increased risk of revision of acetabular cups coated with hydroxyapatite: A swedish hip arthroplasty register study involving 8,043 total hip replacements. Acta Orthopaedica , 81(1):53–59, 2010. [8] Y. Otsuka, K. Kagaya, Y. Hakozaki, Y. Miyashita, and Y. Mutoh. E ff ect of interface damage on loosening behavior of acetabular cup subjected to cyclic loading. Materials Science Forum , 941 MSF:1841–1845, 2018. cited By 0.

Made with FlippingBook Ebook Creator