Fig. 2. Damage behavior of porous simulated bone under cyclic compression at σ a = -0.75 [MPa], R = 10, f = 10Hz.
(a) IR temperature change
(b) Thermal image be fore loading
(c) Thermal image af ter 2 . 0 × 10 3 cycles
Fig. 3. Damage behavior of porous simulated bone under cyclic compression at σ a = -1.8 [MPa], R = 10, f = 10Hz.
dislocation of the cup or its revision. Clinical reports have only emphasized the biological factors, such as osteolysis or infection[2]. Our result firstly revealed the critical mechanical factor to determine the extent of loosening of the acetabular cup.