PSI - Issue 26
L. Martelli et al. / Procedia Structural Integrity 26 (2020) 175–186 Martelli et al. / Structural Integrity Procedia 00 (2019) 000–000
182
8
Primary structure
Coupled system
DLS
LLS
DLS modes
LLS modes
DLS
LLS
DLS modes
LLS modes
0.100
0.100
0.075
0.075
0.050
0.050
Se [g]
Se [g]
0.025
0.025
0.000
0.000
0
1
2
3
4
0
1
2
3
4
T [s]
T [s]
Fig. 7. Horizontal component of elastic pseudo-acceleration response spectra of both structural systems.
Coupled system Primary structure
0.100
0.075
0.050
∆a g ,3
Se [g]
∆a g ,1
0.025
0.000
0
1
2
3
4
T [s]
Fig. 8. Elastic pseudo-acceleration response spectrum for the top three vibration modes, LLS.
∆a g,i Table 2. ∆a g variations between the two systems.
Mode
variation
1 2 3
19% 76%
129%
3.4 Seismic response The linear dynamic analysis has allowed to find seismic response characteristics like maximum floor displacements, inter-storey drift ratios and base shears; they are the main practical quantities to monitor the behaviour of structures from a seismic and vulnerability point of view. Tables 3 and 4 represent peak floor displacements for which Damage and Life-safety Limit States have been considered for the original structure and the combined primary-exoskeleton system; the former also indicates DLS inter-storey drift ratios.
Made with FlippingBook - Share PDF online