Jacopo De Nisi et al. / Procedia Structural Integrity 24 (2019) 541–558
544
Paolo Folgarait et al./ Structural Integrity Procedia 00 (2019) 000 – 000
4
Heat treatments have been performed in a laboratory furnace NABERTHERM model N31/H (using Argon as inert gas), range 100÷1280°C, with wall thermocouples calibrated as per internal procedure PT-7/10 Rev.10. Piece temperature being checked through contact thermocouples connected to an external digital tracker; tracker and thermocouples previously calibrated according to the same internal procedure.
Fig. 1 . Projected samples location on the building platform: a) schematic representation of planned subdivision , b) appearance of the job at the end of the process.
Fig. 2 . 3D printing scheme on the building platform: evidence of specimen distribution (sample mapping) and labelling (the real image of as-built specimen is in Fig.1b). Quadrants Q1 to Q9 are herein labelled as A to I (Q1=A; Q9=I).