PSI - Issue 18

Fokion Oikonomidis et al. / Procedia Structural Integrity 18 (2019) 142–162 Dr okion Oikono idis/ Structural Integrity Procedia 00 (2019) 00 – 000

144

3

Fig. 1. Chain link used for full-scale testing (drawing not to scale).

Fig. 2. [Left] Sketch of the EDM notch and target crack used in the FE models for fatigue pre-cracking (dimensions in mm). [Right] Cyclic bending of chain link to generate fatigue pre-crack after the EDM notch.

Made with FlippingBook - Online magazine maker