Piotr Smarzewski / Procedia Structural Integrity 17 (2019) 5–12 Piotr Smarzewski / Structural Integrity Procedia 00 (2019) 000 – 000

12

8

The presence of 10% silica fume results in the largest increases in mean tensile splitting strength and modulus of elasticity by about 26% and 5%, respectively. The increase in compressive strength is 14% at 25% SF, but the drop does not exceed 1% in the range of 25 to 10% SF. The mean fracture energy is the highest for the HPC with 5% SF content and it is slightly increases by 2% compared to the HPC with 10% SF. The calculated characteristic length indicates that the HPC with 15% SF content is the most brittle. However, the differences of the characteristic length in the SF content range from 10% to 25% do not exceed 5%. A more pronounced decline in the brittleness of HPC has occurred with 5% SF at a w/b ratio of 0.25.

Acknowledgements

The financial support from the Polish Ministry of Science and Higher Education within statutory research project No. S/15/B/1/2019 is greatly appreciated.

References

Ahmad, S.H., Shah, S.P., 1982. Complete triaxial stress – strain curves for concrete. Proceedings of American Society of Civil Engineers 108, 728– 742. ASTM C469/C469M- 14, Standard Test Method for Static Modulus of Elasticity and Poisson’s Ratio of Concrete in Compression; ASTM International: West Conshohocken, PA, USA, 2014. Atis, C.D., Özcan, F., Kılıc, A., Karahan, O., Bilim, C ., Severcan, M.H., 2005. Influence of dry and wet curing conditions on compressive strength of silica fume concrete. Building and Environment 40, 1678 – 83. Duval, R., Kadri, E.H., 1998. Influence of silica fume on the workability and the compressive strength of high-performance concretes. Cement and Concrete Research 28, 533–547. Gesoglu, M., Guneyisi, E., Asaad, D.S., Muhyaddin, G.F., 2016. Properties of low binder ultra-high performance cementitious composites: Comparison of nanosilica and microsilica. Construction and Building Materials 102, 706 – 713. Gettu, R., Shah, S.P., 1994. Fracture mechanics, in “ High performance concretes and applications ” . In: Shah, S.P., Ahmad, S.H. (Eds.). Edward Arnold, London, Melbourne, Auckland, pp. 337. John, R., Shah, S.P., 1989. Fracture mechanics analysis of high-strength concrete. Journal of Materials in Civil Engineering 1, 185–198. Kjellsen, K.O., Hallgren, M., Wallevik, O.H., 2000. Fracture mechanical properties of high -performance concrete – Influence of silica fume. Materials and Structures 33, 552–558. Kjellsen, K.O., Wallevik, O.H., Fjällberg, L., 1998. Microstructure and microchemistry of the paste – aggregate interracial transition zone of high performance concrete. Advances in Cement Research 10, 33 – 40. Köksal, F., Altun, F., Yiğit, Î., Şahin, Y., 2008. Combined effect of silica fume and steel fiber on the mechanical propertie s of high strength concretes. Construction and Building Materials 22, 1874 – 1880. Montgomery, D.C., Design and analysis of experiments, 2nd Edn., John Wiley & Sons, New York, 1984. Peng, Y., Zhang, J., Liu, J., Ke, J., Wang, F., 2015. Properties and microstructure of reactive powder concrete having a high content of phosphorous slag powder and silica fume. Construction and Building Materials 101, 482 – 487. PN-B-19707:2013-10, Cement. Special cement. Composition, specifications and conformity criteria, 2013. PN-EN 12390-3, Testing Hardened Concrete. Compressive Strength of Test Specimens, 2011. PN-EN 12390-6, Testing Hardened Concrete. Tensile Splitting Strength of Test Specimens, 2011. PN-EN 197-1, Cement. Composition, specifications and conformity criteria for common cements, 2012. PN-EN 933-1, Tests for geometrical properties of aggregates. Determination of particle size distribution. Sieving method, 2012. RILEM TC 89-FMT, 1991. Fracture mechanics of concrete – test methods. Size-effect method for determining fracture energy and process zone size of concrete, Materials and Structures 23, 461 – 465. Rong, Z., Sun, W., Xiao, H., Jiang, G., 2015. Effects of nano-SiO2 particles on the mechanical and microstructural properties of ultra-high performance cementitious composites. Cement and Concrete Composites 56, 25 – 31. Sabir, B.B., 1995. High -strength condensed silica fume concrete. Magazine of Concrete Research 47, 219–226. Smarzewski, P., 2019. Influence of basalt-polypropylene fibres on fracture properties of high performance concrete. Composite Structures 209, 23 – 33. Smarzewski, P., 2019. Study of Toughness and Macro/Micro-Crack Development of Fibre-Reinforced Ultra-High Performance Concrete After Exposure to Elevated Temperature. Materials 12, 1210, 1 – 22. Tasdemir, C., Tasdemir, M.A., Lydon, F.D., Ban, B.I.G., 1996. Effects of silica fume and aggregate size on the brittleness of concrete. Cement and Concrete Research 26, 63 – 68. Toutanji, A.H., Bayasi Z., 1999. Effect of curing procedures on properties of silica fume concrete. Cement and Concrete Research 29, 497 – 501. Wedding, P.A., Swamy, R.N., 1986. Properties of high-strength concrete. Cement, Concrete and Aggregates 8, 33–41. Yogendran, V., Langan, B.W., Haque, M.N., Ward, M.A., 1987. Silica fume in high-strength concrete. ACI Materials Journal 84, 124–129. Zhou, F.P., Barr, B.I.G., Lydon, F.D., 1995. Fracture properties of high-strength concrete with varying silica fume content and aggregates. Cement and Concrete Research 25, 543 – 552.

Made with FlippingBook Digital Publishing Software