PSI - Issue 16
Vitalii Knysh et al. / Procedia Structural Integrity 16 (2019) 73–80 Vitalii Knysh et al. / Structural Integrity Procedia 00 (2019) 000 – 000
78
6
was somewhat higher than on the surface, strengthened by HFMI, and after 2400 hours it was approximately 0.184 mm/y (millimetres per year) and 0.162 mm/y, respectively. The results of metallographic and corrosion tests at high humidity affirmed that application of HFMI technology helps increase of corrosion resistance of the welding joint with a strengthened layer, despite it has a local damage.
0
240 h
720 h
1200 h
2400 h
grounded surface
0
240 h
720 h
1200 h
2400 h
HFMI treated and grounded surface
Fig. 4. Surface of 15KhSND steel base metal after corrosion tests at high humidity and removal of corrosion products.
і cor , mm/year
0,15 0,20 0,25 0,30 0,35 0,40 0,45
2
1
0
500 1000 1500 2000
, hours
, години
Fig. 5. Corrosion rate during testing at high humidity 2400 hours of 15KhSND steel base metal (1) and HFMI treated metal (2).