PSI - Issue 14
Shubha Javagal et al. / Procedia Structural Integrity 14 (2019) 907–914 Shubha Javagal et, al. / Structural Integrity Procedia 00 (2018) 000–000
910
4
Table 4. Various cases considered for analysis .
Thickness of Top plate (mm)
Thickness of Bottom plate (mm)
Figure
Cases of study
1.44
1.44
Case 1 (between 90° and 90° plies)
(8 plies)
(8 plies)
1.62
1.26
Case 2 (between 90° and 0° plies)
(9 plies)
(7 plies)
1.8
1.08
Case 3 (between 0° and -45° plies)
(10 plies)
(6 plies)
1.98
0.90
Case 4 (between - 45° and +45° plies)
(11 plies)
(5 plies)
2.16
0.72
Case 5 (between +45° and 90° plies)
(12 plies)
(4 plies)
2.34
0.54
Case 6 (between 90° and 0° plies)
(13 plies)
(3 plies)
2.52
0.36
Case 7 (between 0° and -45° plies)
(14 plies)
(2 plies)
2.7
0.18
Case 8 (between - 45° and +45° plies)
(15 plies)
(1 plies)