E. M. Strungar et alii, Frattura ed Integrità Strutturale, 68 (2024) 63-76; DOI: 10.3221/IGF-ESIS.68.04

Figure 2: Loading diagrams of specimens of each scheme (a), scatter of maximum/minimum values of ultimate load for schemes A, B, C, E, F (b).

Mech. prop.\ Schemes Max load, kN Max. displacement, mm Ultimate Stress, MPa

G

A

B

C

D

E

F

61.50

35.50

33.30

34.40

21.70

32.70

32.50

7.12

4.39

4.50

4.30

3.08

4.59

4.32

295.50

168.50

157.50

165.00

103.50

154.00

156.50

Table 2: Results of tensile testing of FRP specimens.

The plates were subjected to static tension, and the properties were determined on solid specimens without a concentrator. Mechanical characteristics of the samples: E 11 = E 22 = E 33 = 24,6 GPa; ν 12 = ν 13 = ν 23 =0,128; G 12 = G 13 = G 23 =2,9 GPa.