Issue 59

J.L. González -Velázquez et alii, Frattura ed Integrità Strutturale, 59 (2022) 105-114; DOI: 10.3221/IGF-ESIS.59.08

Figure 5: Photographic records of zones of non-metallic inclusions detected by PAUT in the pressure vessel.

Tab. 2 shows the dimensions of the zones of NMIs detected by the non-destructive inspection in the pressure vessel.

Defect ID

Wall thickness away of lamination ( t rd )

Long. dimension (s)

Circ. dimension (c)

Minimum measured thickness ( t mm )

Lamination height ( L h )

Lamination to lamination spacing ( L s )

Spacing to a nearest major discontinuity ( L msd )

Spacing to nearest weld joint ( L w )

ENV-3.2 ENV-2.4 TP-1.6 TP-2.23 TP-2.24

1.046 1.014 1.098 1.112 1.112

16.00 13.00 7.50 14.00 12.50

14.00 10.00 6.50 16.50 22.00

0.296 0.582 0.296 0.287 0.278

0.630 0.242 0.720 0.552 0.616

40 40

35.83 13.78 16.50

0.5

14.0 30.0 34.0

22.5 16.5 16.5

3.00 6.00

17.5 Table 2: Dimensions of the zones of non-metallic inclusions detected in the pressure vessel (All dimensions in inches).

FFS ASSESSMENT OF INCLUSION ZONES BY P ART 13 OF API 579

ab. 3 presents the results of Part 13 of API 579 Level 1 assessment of the zones of non-metallic inclusions listed in Tab. 2, regarding them as laminations, and evaluated according to the procedure described in section 2.2 of this paper. The sequence of steps was modified to display the calculations in a rational order. T

110

Made with FlippingBook Digital Publishing Software