Issue 77

N. A. Alang et al., Fracture and Structural Integrity, 77 (2026) 340-361; DOI: 10.3221/IGF-ESIS.77.20

(a)

(b) Figure 1: (a) Dimension of uniaxial tensile test specimens (b) Uniaxial tensile and pre-straining test setup.

Specimen ID SP_AR_01 SP_AR_02 SP_4%_01 SP_4%_02 SP_8%_01 SP_8%_02 SP_12%_01 SP_12%_02

Specimen Condition

As received

4% Pre-strained

8% Pre-strained

12% Pre-strained

Table 2: Small punch test matrix.

Figure 2: Small punch test setup.

344