PSI - Issue 77

Carolina Francisco et al. / Procedia Structural Integrity 77 (2026) 567–574 C. Francisco et al. / Structural Integrity Procedia 00 (2026) 000–000

573

7

(a) No load.

(b) Load.

(c) Overload.

Fig. 6: Frame acceleration signals.

(a)No load

(b) Load

Fig. 7: Shaft bearing housing acceleration signals.

and reaction forces. Therefore, analyzing these signals makes it possible to monitor multiple components simultane ously using a single measurement.

4. Conclusions

A sensing plan was developed to monitor the health of a stamping press throughout its operating phase. It includes load sensors on the tool and frame, accelerometers on the slide, frame, and gearbox, temperature sensors on the

Made with FlippingBook flipbook maker