Issue 76
H. Houri et alii, Fracture and Structural Integrity, 76 (2026) 238-264; DOI: 10.3221/IGF-ESIS.76.15
configuration with L = 20 mm proves to be the most favorable, as it minimizes strain localization while promoting overall homogeneity in the material.
a (L=20mm)
b (L=30mm)
c (L=40mm) d (L=50mm) Figure 11: Distribution of the equivalent plastic strain along the selected cross-section (20 mm) for different corner angles in the case of the 105° 2-ECAE die.
0,0 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8 Equivalente Plastic Strain
L = 20 mm L = 30 mm L = 40 mm L = 50 mm
0,0
0,2
0,4
0,6
0,8
1,0
Normalized Distance
Figure 12: Distribution of the equivalent plastic strain along the selected cross-section for φ = 15° at different channel lengths in the case of the 105° 2-ECAE die.
251
Made with FlippingBook - Share PDF online