Juraj Králik et al. / Procedia Structural Integrity 73 (2025) 73–80 Juraj Králik/ Structural Integrity Procedia 00 (2025) 000–000
77 5
Fig. 5. The roof zones with wind load in the -X direction determined by Eurocode requirements.
Fig. 6. The view of NPP objects from the -Y and +Y sides.
Table 1. Comparison of the external pressure coefficients for flat roofs in accordance with Eurocode and experiment.
Zone
Roof type
F
G
H
I
c pe,10 -1.90 -1.83
c pe,1
c pe,10 -1.30 -1.68
c pe,1
c pe,10 -0.70 -0.80
c pe,1
c pe,10
c pe,1
+0.2 -0.2 -0.73
Sharp gutters - Eurocode Sharp gutters - Experiment
-2.50
-2.00
-1.20
-
-
-
Table 2. External pressure coefficients for flat roofs in accordance with numerical analysis. Location / zone 490 G H H G
I
-0.73
-0.75
-0.48
-0.59
-0.42
c pe,10
805
805 Skylight
Location / zone
F
G
H
H
F
-0.32
-0.03
-0.32
-0.01
0.02
c pe,10
805 Skylight
800
Vent. centre
Location / zone
G
F
G
H
H
0.07
-0.87
-0.88
-0.53
-0.31
c pe,10
Vent. centre
Bubble tower
807
Location / zone
I
I
H
I
-0.29
-0.27
-0.42
-0.44
c pe,10
807 Shelter
Location / zone
H
I
-0.43
-0.45
c pe,10