PSI - Issue 71
Priti Kotak Shah et al. / Procedia Structural Integrity 71 (2025) 271–278
274
Fig.3. Typical stress-strain plots of tested clads of different types
Fig.4. Typical appearance of untested and tested samples of various types
0 100 200 300 400 500 600 700 As-Fab HydRim1 HydRim2 HydUni1 HydUni2 HydUni3 Yield Strength (MPa) Condition of Clad Tube 0 100 200 300 400 500 600 700 800 As-Fab HydRim1 HydRim2 HydUni1 HydUni2 HydUni3 UTS (MPa) Condition of Clad Tube
Fig.5. Bar chart showing variation in yield strength for different clad specimens obtained in RTT
Fig.6. Bar chart showing variation in ultimate tensile strength for different clad specimens obtained in RTT
Made with FlippingBook Digital Proposal Maker