S. Eleonsky et alii, Fracture and Structural Integrity, 71 (2025) 246-262; DOI: 10.3221/IGF-ESIS.71.18

and dynamic case. This fact is very unobvious until the presented studies have been carried out even though static contact case is of interest. It is quite clear that the degree of composite surface plate damage around contact interaction area under impact influence is much higher that in the case of static indentation.

(a)   u N 14.5 (b)   u N 11.5 Figure 8: Interference fringe patterns generated by trough hole drilling at point 1 of D_1 coupon in terms of in-plane displacement component u (a) and v (b).

(a)   u N 9.0 (b)   u N 10.0 Figure 9: Interference fringe patterns generated by trough hole drilling at point 2 of D_1 coupon in terms of in-plane displacement component u (a) and v (b).

253