Issue 70
H. Siguerdjidjene et alii, Frattura ed Integrità Strutturale, 70 (2024) 1-23; DOI: 10.3221/IGF-ESIS.70.01
10
10
FGM-AL/SiC Notched Plate (n=1.0) and H=2.00 mm
r=1.66 mm r=2.50 mm r=3.34 mm r=4.16 mm r=5.00 mm
8
8
6
6
4
4
Load (KN)
Initial crack r=1.66 mm r=2.50 mm r=3.34 mm r=4.16 mm r=5.00 mm
Crack length (mm)
2
2
0,0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 0
0
Displacement (mm)
Figure 11: Load-displacement response and crack length of FGM (Al/SiC) for the exponent fraction n=1.0.
Figure 12: Critical crack length with stress field of an FGM (Al/SiC) plate for n=1 and different notch diameters; a) Ceramic-rich surface, b) Metal-rich surface
17