Issue 70

A. Chulkov et alii, Frattura ed Integrità Strutturale, 70 (2024) 177-191; DOI: 10.3221/IGF-ESIS.70.10

a)

b)

c)

d)

Figure 2: Simulated thermograms (Train 1 dataset) at times 0.3 s (a), 0.7 s (b), 1.5 s (c) and 5 s after heating. The temperature evolutions at defect and non-defect points are presented in Fig. 3 in the Log-Log scale. The blue curves represent temperature evolutions over the defect centers. The red curves represent non-defect temperature evolutions at the corner points, in the middle of the sample and between the defects.

Figure 3: Modelled temperature evolutions at defect (blue) and non-defect (red) points (Log T vs. Log t ).

184

Made with FlippingBook Digital Publishing Software