PSI - Issue 69
Diego Scaccabarozzi et al. / Procedia Structural Integrity 69 (2025) 80–88
85
Table 2: Transformation temperatures detected from the DSC scans
Af [°C] Ms [°C] Mf [°C] [° ] Rf [°C]
As [°C]
As built
-27.5
15.9
3.7
-61.9
-
-
After (T500-5’)
-0.8
20.0
-31.3
-58.5
13.2
-17.6
After (T500-10’)
3.5
18.3
-27.9
-53.3
9.6
-0.6
Damping Properties In Fig. 5 acquired vibrometer waveform and related FRF are shown.