PSI - Issue 66
7
S. Skrobacz et al. / Procedia Structural Integrity 66 (2024) 11–25 S. Skrobacz¹², P. Krysi ń ski¹, S. Ma ł ys¹², T. Ł agoda², / Structural Integrity Procedia 00 (2025) 000–000
17
③
④
Figure 5. Macrographic Cross-Sections of Sample Number PR-906
Table 4. Description of 2Y Joint for Sample PR-907 - Sketch of the Sample, Notes, and Detected Defects
Welding Position/Method
Type of Joint
Type of Weld
Filler Material
Shielding Gas
BW
2Y
PA
131(robot)
AlMg4.5MnZr
I1 (Ar100%)
Sketch of the Sample
1: End with Gas Porosity; 2011; d ₘ ₐₓ = 0.1 mm; d ₐ ≤ 0.6mm 2: 504; h ₘ ₐₓ = 1.8 mm; h ₐ ≤ 3.0mm 3: 504; h ₘ ₐₓ = 3.2 mm; h ₐ ≤ 3.0mm
Notes, and Detected Defects
Made with FlippingBook Ebook Creator